sonostar equipment co., LTD
|
Place of Origin: | Guangdong, China (Mainland) |
Add to My Favorites | |
HiSupplier Escrow |
Physical Specifications | |||||
Dimension Weight | Dimension | 32cm (W)*26cm (D)*9cm (H) | |||
Weight | standard configuration: 2.8 kg | ||||
Operation Environment | Power requirements | AC100-240V , 50/60Hz | |||
Power | 50VA | ||||
Temperature | 5-40℃ | ||||
Humidity | 30-93% non-condensing | ||||
Fetal Performance Specifications | |||||
Performance Specifications | Display | 10.1inch (800X600 pixel) color TFT –LCD | |||
Indicator | Visual on-display and integrated, alarm light, audible alarm | ||||
Battery | Internal rechargeable Li-ion battery power | ||||
Alarm | Visual on-display and integrated, alarm light, audible alarm | ||||
Memory | 24-hours memory for fetal traces | ||||
Printer | America standard/international standard Built-in thermal printer (112mm) 1/2/3cm/min real-time printing speed, fast print speed (stored traces) | ||||
Paper | Z-fold, thermosensitive | ||||
Record Message | ID, name, age, date, time, print speed etc | ||||
CMS | Support connecting to central monitoring station through LAN (TCP/IP) or wireless connection | ||||
Fetal Technical Specifications | |||||
Ultrasound (FHR) | Measurement range | US | 50 to 240 bpm | ||
Resolution | Display | 1bpm | |||
Printer | 1bpm | ||||
jitter@200 bpm | ≤3bpm | ||||
Display update rate | 0.25second | ||||
Beat to bea change(max.) for ultrasound | 28bpm | ||||
US frequency | 1MHz±5%Hz | ||||
TOCO | Measurement method | Strain gauge sensor element | |||
Sensitivity | 1 unit =2.5g | ||||
Resolution | 1 unit | ||||
Measurement range | 500 units | ||||
Baseline setting | 0, 5,10, 15, 20 can be selective | ||||
Update rate | 0.25 second | ||||
Auto offset correction | 3 second after connecting the transducer | ||||
Auto zero adjust | TOCO value is set to zero negative following a negative .Measure value for 5 seconds | ||||
Auto Fetal Movement (AFM) | Technique | Pulsed doppler ultrasound | |||
Range | 0-100% | ||||
Resolution | 1% | ||||
Automatic fetal movement actograph | |||||
Manual fetal movement mark | |||||
Maternal ECG (MECG) | Heart rate range | 30~300bpm | |||
Resolution | 1bpm | ||||
Accuracy | ±1bpm/ ±1% | ||||
Leads | I, II, III, avL, avR, avF, V | ||||
Sweep speed | 12.5mm/s, 25mm/s, 50mm/s | ||||
Gain selection | x 0.25, x0.5 ,x1, x2 | ||||
Operation mode | diagnostic, monitor, surgery | ||||
Temperature (TEMP) | Technique | Thermistor probe CYSI 400 series compatible | |||
Measurement range | 0℃-50℃ | ||||
Accuracy | ±0.1℃ | ||||