Features:
-12" color TFT display, up to 12 waveforms
-One level menu, easy to use
-Parameters including ECG/RESP, SpO2 , NIBP, TEMP, Pulse Rate and IBP(optional)
-Maximum 720 hour graphic and tabular trends of all parameters
-Built-in recorder and battery
-Suitable for adult, pediatric and neonatal patient
-Arrhythmia analysis, ST calculation, Pace analysis
-Anti-ESU, anti-
defibrillator
-Standard network interface, can connect to Central monitor system
Main Functions:
1. 12" widescreen TFT, Resolution ratio: 800×600, up to 12 waveforms ;
2. Display ECG, SpO2, pulse rate, NIBP, respiration, temperature
3. Plumbic acid battery.
Optional:
1. Recorder(Built-in)
2. CO2
3. Anesthesia depth
1 Classification
Item | Specification |
SFDA classification | Class II |
Anti-electroshock degree | Class I equipment with internal power supply |
Anti-electroshock degree | TEMP/SpO2/NIBP: ECG/RESP | BF CF |
Explosion proof level | Ordinary equipment,without explosion proof |
Harmful liquid proof degree | Ordinary equipment,without liquid proof |
Working system | Continuous running equipment |
Medical electrical equipment GB 9706.1-2007, Part I: General requirements for safety
GB 9706.25-2005 Medical electrical equipment Part 2-27: ECG monitoring equipment safety requirements
YY 1079-2008 ECG
YY0667-2008 Medical electrical equipment Part 2: Automatic cycling non-invasive blood pressure monitoring equipment, safety and essential performance
YY0668-2008 Medical electrical equipment Part 2: multi-parameter patient monitoring equipment requirements for the safety
3 monitor size and weight
size 300 ×275 ×150 mm
Weight 4 kg
4 Power Supply
100~240 VAC, 50/60 Hz, Pmax=90VA Fuse T1.5A
2.6 Ah 12V rechargeable battery
Operating time after full charge is more than 1 hours
Operating time after the first alarm of low battery will be about 5 minutes
Maximum charging time is less than 6 hours.
Network interface standard RJ45 Socket
Trend 720 hours
NIBP review 1000 NIBP events
Wave review 2 hours
Alarm review 200 alarm events
All storage data are non volatile.
8.1 Temperature
Working 0 ~ 40 °C
Storage -20 ~ 50°C
8.2 Humidity
Working 15% - 90 %(no coagulation)
Storage 15% - 90 % (no coagulation)
8.3 Atmospheric pressure
Working 86.0 kPa ~ 106.0kPa;
Storage 86.0 kPa ~ 106.0kPa
9.1 Heart rate calculation method
Since the first occurrence of heart rate to heart rate occurred in the second interval T1; second heart rate, heart rate occurred to a third place time interval T2; continuous record 10 times, and then calculated the average interval of 10, must the heart rate per minute. 3s ~ 10s refresh every heart.
9.2 Heart rate meter accuracy and arrhythmia response
Monitor the 20s stable time after figure ECG heart rate a wave group): heart rate display 40bpm ± 5bpm; b): heart rate display 30bpm ±5bpm; c): heart rate display 120bpm±5bpm; d): heart rate display 45bpm±5bpm
A) Couple rhythm — two waves of duration is 1500ms; if the calculation all the QRS complex, heart rate to 80bpm, if only large R wave or S-wave, the heart rate to 40bpm.
B) Slow change couple rhythm — if the calculation all the QRS complex, heart rate to calculate 60bpm, if only large waves, heart rate to 30bpm.
C) Fast couple rhythm — if the calculation all the QRS complex, heart rate as 120bpm.
D) bi-directional contraction — if you calculate the QRS complex, heart rate to calculate 90bpm, if only large waves, heart rate to 45bpm.